| Wissenschaftliche Publikationen |
| AUTOR |
TITEL |
ZEITSCHRIFT |
G. Farin 1), K. E. Grund 2)
1) Erbe Elektromedizin, Tübingen/Germany
2) Department of General Surgery and Endoscopy, Eberhard-Karls University, Tübingen, Germany
|
Technology of Argon Plasma Coagulation with Particular Regard to Endoscopic Applications
|
In: Endoscopic Surgery and Allied Technologies |
Michael J. Sessler / Horst-Dieter Becker / Ingo Flesch /
Karl-Ernst Grund, Department of General Surgery, Eberhard-Karls University, Tübingen, Germany |
Therapeutic effect of argon plasma coagulation
on small malignant gastroentestinal tumors
Ref: Argon-Plasma Coagulation Unit APC 300 and high-frequency surgical unit of ERBE Elektromedizin, Tübingen |
In: Journal of Cancer Research and Clinical Oncology. 1995, 121: 235-238 |
Jerome D. Waye, M.D.
Clinical Professor of Medicine, Mount Sinai Medical Center,
New York, N.Y./USA
|
Delivery System for Argon Coagulator Offers Non-Contact Method for Control of GI Bleeding
Ref: APC 300 Argon Plasma Coagulator |
In: Gastroenterology & Endoscopy News, June 1997 |
Jerome D. Waye, M.D.
Clinical Professor of Med.
GI Endoscopy Unit, Mount Sinai Hospital & Lenox Hill Hospital, New York, NY/USA
|
Argon Plasma Coagulator: Should Everyone Have One?
Ref: ERBE ICC ENDO CUT, APC 300 |
In: Surgical Technology International VII, 1998 |
Kohler, M. Maier, C. Benz, W.R. Martin, G. Farin, J.F. Riemann, Dept. of Gastroenterology, Academic Medical Hospital, Ludwigshafen/Germany
Erbe Elektromedizin, Tübingen/Germany
|
A New HF Current Generator With Automatically Controlled System (Endocut Mode) for Endoscopic Sphincterotomy – Preliminary Experience
Ref: ICC 200, ICC Endocut |
In: Endoscopy 1998; 30: 351-355 |
| Gostout, Mayo Clinic, Rochester; Waye, Mount Sinai Medical Center, New York City, Vargo, The Clevelend Clinic Foundation; Kozarek, Virginia Mason Medical Center & Univ. of Washington School of Medicine, Seattle; Cohen, NYU School of Medicine, New York City; |
Physicians Agree: Argon Plasma Coagulator Is Safe, Versatile, Efficacious, Easy to Master.
Ref:: APC 300, ICC EndoCut |
In: Gastroenterology & Endoscopy News, Special Report 1999 |
A. May 1) , L. Gossner 1) , E. Günter 1), M. Stolte 2) , C. Ell 1);
1) Dept. of Medicine, Klinikum Wiesbaden, Germany, 2) Institute of Pathology, Klinikum Bayreuth, Germany |
Local Treatment of Early Cancer in Short Barrett’s Esophagus by Means of Argon Plasma Coagulation: Initial Experience
Ref: Argon Beam Device, Argon Beamer 2 |
In: Endoscopy 1999; 31 (6): 497-500 |
J. M. Canard 1), B. Védrenne 2),
1) Centre Médico-Chirurgical du Trocadéro, Paris, France, 2) Centre Hospitalier de Mulhouse, Mulhouse, France |
Clinical Application of Argon Plasma Coagulation in Gastrointestinal Endoscopy:
Has the Time Come to Replace the Laser?
|
In: Endoscopy 2001; 33 (4): 353-357 |
| T Sagawa, T Takayama, T Oku, T Hayashi, H Ota, T Okamoto, H Muramatsu, S Katsuki, Y Sato, J Kato, Y Niitsu, |
Argon plasma coagulation for successful treatment of early gastric cancer wih intramucosal invasion
|
Reprinted from GUT, March 2003, Vol 52, No 3, p 334-339) |
Fuchs / Hamelmann /
Manegold
(Hrsg.) |
Chirurgische Endoskopie im Abdomen
Ref: ACC 450 |
133-134/ 286287/347-351
Blackwell Wissenschaft, Berlin 1992 |
Grund / Storek / Zindel / Becker, Univ. Tübingen |
Hochflexible
selbstexpandierende Metallgitterstents: Neuartige Palliativtherapie
der malignen Dysphagie
Ref: Argon-Plasma-Coagulation |
from: Z Gastgroenterol 1995; 33: 392-398 |
Sessler / Becker / Grund
Univ. Tübingen |
Palliativtherapie
beim kleinen Ösophaguskarzinom: ist die Argon-Plasma-Koagulation
(APC) als Alternative sinnvoll?
Ref: Hochfrequenzenergie-Einheit Erbe Elektromedizin |
aus: Endoskopie heute 3/95; 240-244 |
| |
 |
|
Grund / Zindel / Storek
Univ. Tübingen |
Endoskopische
Therapie von Stenosen im Gastrotentinaltrakt
Ref: Argon Plasma Coagulation |
aus: Chirurgische Gastroenterologie 1996; 12:120-128 |
G. Focke (1), Ch. Seidl (2), V. Grouls (2)
Innere Klinik II (1), Institut für Pathologie (2), Stadtkrankenhaus, Worms |
Behandlung
des Wassermelonen-Magens (GAVE-Syndrom) mit der endoskopischen
Argon-Plasma-Koagulation (APC).
Ein neuer Therapieansatz.
Ref: Argongas-Koagulationssonde, Argongasquelle, Hochfrequenz-Generator,
alle Fa. Erbe, Tübingen |
aus: Leber-Magen-Darm, 26. Bd., Sept. 1996, S. 254-259 |
P.J. Wahab, C.H.H. Mulder, G. den Hartog, J.E. Thies,
Dept. of Hepatogastro-enterology, Rijnstate Hospital, Arnhem, NL |
Argon Plasma Coagulation in Flexible
Gastrointestinal Endoscopy: Pilot Experiences
Ref: APC probe, argon gas source, ICC 200 |
Endoscopy 1997; 29; 176-181 |
Pross, Manger, Schulz, Lippert, Klinik u. Poliklinik für Chirurgie, Otto-von Guericke-Univ. Magdeburg |
Die Therapie der Anastomosenstenose
nach Resektionsverfahren im Kolorektum
Ref: ICC 200 Endocut, Beamer Two |
Viszeralchirurgie 33 (1998) 222-225 |